Faulty expansion tank: 5 common problems

click fraud protection
Home page»DIY»installation»warmth»Faulty expansion tank: 5 common problems
author
Home editorial office
4 minutes

Table of contents

  • Expansion tank - function
  • signs
  • membrane rupture
  • Wrong size
  • Wrong pressure
  • Leaking valve
  • Wrong gas

The expansion tank of the heating system fulfills important tasks. If it is defective, this can result in several problems. Regular maintenance and repairs can prevent problems with the expansion tank and thus with heating.

video tip

Expansion tank - function

The expansion tank consists of a chamber divided into two areas by a diaphragm. One area is filled with water that can be fed to the heating system. The other has gas. This is usually nitrogen, as this can prevent corrosion.

When water is heated, its volume increases. This moves the membrane. The gas is compressed. If the temperature decreases again, the volume of the water also decreases. The membrane moves back and the gas has more room to expand again. This also allows water to flow back into the heating circuit. However, this is not possible in the case of defects or other problems.

signs

Signs of a defective expansion tank or problems in the surge tank include:

  • "gurgling" noises
  • escaping water at the safety valve
  • significant pressure fluctuations during heating
  • lack of heating power, only slight warming
  • cold or unevenly warm radiators

membrane rupture

A rupture in the membrane between the chambers, which are filled with water and gas, is particularly problematic. Because in this case, the two substances can mix and the heating power drops significantly, while the pressure fluctuates greatly.

Changing the membrane is not possible. Instead, the entire expansion tank must be replaced. An installer should be consulted for this. However, the container can also be replaced by yourself if the correct procedure is observed.

Wrong size

If the wrong size was selected for the pressure equalization tank, the pressure cannot be equalized accordingly. In order to calculate the correct size, the design of the heating system must be taken into account. In addition, the following factors are also important:

  • amount of heating water
  • operating temperatur
  • response pressure

A corresponding vessel can already be purchased very cheaply. Prices range between around 30 and 100 euros.

Wrong pressure

The working range of the expansion tank must be adjusted correctly. Otherwise problems may arise. For the working area, it should be considered that this is at least 0.3 bar above the minimum pressure. Otherwise, negative pressure can occur, which can have a negative effect on the entire system.

Tip:

Apps or PC programs that are in the Usually offered directly by the manufacturers and designed for the respective heating system and the pressure expansion tank are.

If the operating pressure is too high, water will escape from the safety valve. In addition to the dripping valve, a clear sign of this is that there are high heating water losses and the system has to be refilled accordingly.

expansion tank construction

Another problem in the area of ​​pressure can be the already mentioned minimum pressure. This leads to:

  • noises
  • Decreased performance
  • shutdown of the boiler

Just as with an incorrectly set initial pressure, the container can also fill up, so that no there is sufficient space if heated heating water is included with a larger volume must become.

Leaking valve

The purpose of the safety valve is to prevent excess pressure if necessary and to drain water for this purpose. For this purpose, the valve is opened from a certain pressure and the pressure is released.

However, if the valve is leaking, water will escape even at a significantly lower pressure and no corresponding operating pressure can be built up.

Wrong gas

If there is oxygen in the gas section, it can corrode the metal in the event of a leak. This in turn results in weak points and defects that can result in costly repairs and the purchase of spare parts. The gas tank should therefore always be filled with nitrogen.

author Home editorial office

Learn more about heat

Cooling capacity air conditioning
warmth

Calculate cooling capacity BTU/hr of an air conditioner

If you want to buy an air conditioner, you should know the required performance. This is often given in BTU/h. You can find out what this is all about and how you can easily calculate the cooling capacity of an air conditioning system in our guide.

heat pump
warmth

Combining heat pumps with photovoltaics: experiences

Does it make sense to combine a heat pump with a photovoltaic system? Home builders are right to ask this question, because if you already rely on a sustainable heating system, it can only be right to produce some of the electricity required for operation yourself, or?

expansion tank construction
warmth

Calculate heating expansion tank | Table & Formula

How large an expansion tank in heating systems has to be and what pressure it can generate and withstand depends on various factors. The following tips and the table below show what is important when selecting a pressure equalization tank or expansion tank.

warmth

Checking the heating expansion vessel: checklist

The heater's expansion tank serves an important purpose as it absorbs excess water from the system and equalizes the pressure when necessary. In order to prevent defects, it is therefore crucial to carry out regular checks.

warmth

Radiator valve is stuck | 4 tips to solve the thermostat

If the heating does not want to warm up, there is a high probability that the radiator valve is stuck. Luckily, you don't need a specialist to make it work again. Here are a few tips on how to undo the part yourself.

warmth

Change the heating thermostat and set it correctly

Changing the heating thermostat and setting it correctly is very easy, even for laypeople, with the right knowledge and the right instructions. However, there are a few factors to consider when setting it up. We reveal what is important.

Sign up to our newsletter

Pellentesque dui, non felis. Maecenas male